Hematology
XN-350

XN-350 brings the same clinical values to low and medium volume labs with a single open tube mode hematology analyzer that offers an expanded clinical value.
Onboard Rules to standardize manual rerun/reflex based on your own criteria. Reticulocyte profile and body fluid analysis are also available. It offers the most advanced hematology technology for the community clinical laboratory with the same technology that is offered for a hospital and reference laboratory.
The IG parameter is a biomarker of inflammation and infection that can contribute to the diagnosis of sepsis among other processes. It is a reportable parameter from the six part differential provided by the instrument.
XN-450

XN-450 with a single closed or open tube mode brings the same clinical and operational values to low and medium-volume labs.
LOW WBC application improves the reliability of the analysis in samples with low WBC counts. XN-L provides a 6-part differential (including Immature Granulocytes) on every sample, aiding in the assessment of sepsis and other hematological disorders.
Onboard Rules provide efficient standardization of rerun and reflex based on your own criteria. Reticulocyte profile and body fluid analysis are also available. It offers the most advanced hematology technology for the community clinical laboratory with the same technology that is offered for a hospital and reference laboratory.
XN-550

The introduction of the XN-Series hematology analyzers has helped Sysmex become the market leader in CBC testing performed by large and midvolume labs.
XN-L series brings the same clinical and operational values to low and medium volume labs with automated hematology analyzers offer expanded clinical value.
LOW WBC application (Standard) improves reliability of analysis, XN-L provides a 6 part differential (including Immature Granulocytes) on every sample aiding in the assessment of sepsis and other hematological disorders, Onboard Rules provide efficient rerun/reflex based on your criteria.
XN-1000

Capable of processing 100 samples per hour. Onboard decision rules and advanced parameters are standard offerings. Provides advanced clinical parameters:
Leukopoietic indicators—Immature Granulocytes with every differential
Erythropoietic indicators—Nucleated RBC with every CBC, Reticulocyte Hemoglobin (RET-He) and Immature Reticulocyte Fraction (IRF)
Immature Platelet Fraction (IPF) and a Fluorescent Platelet Count (Plt-F) designed for recheck platelets counts.
Body Fluid Mode with RBC and WBC counts and two part differential
XN-2000

An integrated co-primary hematology system with two analytical modules capable of processing 200 samples per hour. Provides advanced clinical parameters:
Leukopoietic indicators—Immature Granulocytes with every differential
Erythropoietic indicators—Nucleated RBC with every CBC, Reticulocyte Hemoglobin (RET-He) and Immature Reticulocyte Fraction (IRF). Reticulocyte Hemoglobin, Immature Reticulocyte Fraction
Thrombopoietic indicators—Immature Platelet Fraction (IPF) and a Fluorescent Platelet Count (PLT-F) designed for very low platelet counts. Immature Platelet Fraction (IPF) and a Fluorescent Platelet Count (Plt-F) designed for recheck platelets counts
The series-wide compact design delivers a smaller footprint for increased physical productivity. Sysmex’s leading-edge technology and unmatched expertise deliver the tools you need to build the lab of tomorrow.
Body Fluid Mode with RBC and WBC counts and two part differential
Aerospray Hematology Pro Slide Stainer

The Aerospray Pro Slide Stainer/Cytocentrifuge automates the staining of blood and other body fluids to facilitate enhanced clarity using a rapid stain mode, a longer Wright-Giemsa mode, a May Grünwald Giemsa (MGG) mode or custom settings.
Staining Advantages
Superior staining process that is easy to use and saves time
Rapid performance cycle time
Cross-contamination is eliminated with a fresh application of stain
Automated nozzle clean after each stain cycle reduces maintenance.
Convenient automated waste level detection (optional)
Superb cytocentrifuge, resulting in a five-to nine-fold increase in the number of cells on a slide (optional).
Programmable functions to accommodate different intensities, and personal preferences
Laboratory compliance with traceability features is ensured
minííSED

minííSED offers highly efficient ESR testing in a compact footprint. Best for low volume laboratories, minííSED brings a novel approach to ESR testing by directly measuring RBC aggregation with capillary photometry during rouleaux formation.
Capped primary EDTA tube can be directly inserted into the instrument, and sampling and reading is performed by miniiSED to significantly improve turnaround time and reduce hands-on time.
Results in 15 seconds.
Automated ESR testing in a compact footprint.
Sampling directly from primary EDTA tube.
100 µl aspirated volume (500 µl total sample volume).
No disposables.
Compatible with pediatric tubes.
íSED

Brings a novel approach to ESR by directly measuring RBC aggregation with capillary photometry during rouleaux formation. Capped primary EDTA tubes can be directly inserted into the instrument, and mixing, sampling, and reading is performed by íSED for true walk-away automation. Compared to the Westergren method, íSED requires >96% less hands-on time and reduces turnaround time up to 94%.
Results within 20 seconds.
Walk-away automation / less than 3 seconds hands-on time.
Sampling from primary EDTA tube.
100 µl aspirated volume (500 µl total sample volume required).
Compatible with pediatric tubes.
Random access / continuous feed operation / up to 20 samples.
No disposables.
XN-3100

This bench top unit includes two co-primary hematology analytical modules integrated with a SP-50, 5th generation slidemaker-stainer.
The DI-60 cell image analyzer and a floor-standing wagon for system and reagents are optional upgrades. The XN-3100 provides advanced clinical parameters, including NRBCs with every CBC, Immature Granulocytes with every diff, RET-He within the Reticulocyte profile and a fluorescent platelet channel for the Immature Platelet Fraction (IPF), RET-He and Immature Reticulocyte Fraction (IRF) within the Reticulocyte profile.
The series-wide compact design delivers a smaller footprint for increased physical productivity.
Sysmex XN-3100 Automated Hematology Analyzer Overview:
Two XN-10 Analyzers
Smart sampler - for automated rerun/reflex testing
Slidemaker-stainer (SP-50)
Onboard decision rules
Body fluid mode
PLT-F (fluorescent platelet) discrete testing channel
Reticulocyte channel
Status alert light